SO6192 | |
---|---|
Type | MPPT SOLAR CHARGE CONTROLLER |
Model | SO6192 |
INPUT | |
Input Voltage Range | 100V ~ 300V (Wide input voltage range) |
180V ~ 260V (Normal input voltage range) | |
Nominal Input Voltage(s) Supported | 220V AC, 50Hz |
Input connection type | Hard Wire |
BATTERY Full Load Runtime (minutes) | Depends on Load & Battery AH |
No of Battery | 16 |
Solar Charge Controller | |
Type | MPPT/PWM |
Max.PV Open Circuit Array Volatge | 352VDC |
Charge Algorithm | 3-stage Bulk / Acceptance / Float Plus Equalize |
LCD Display | Backlit, Alphanumeric Display showing battery voltage, DC amperage, Cumulative KW hours |
OUTPUT | |
Output Volt Amp Capacity (VA) | 6000 |
Output Watt Capacity (watts) | 4800W |
DC System Voltage (VDC) | 192V |
Load Capacity | >110% faulty after 300ms |
Phases | 1Phase – 3 Wire (L.N.E) |
Output AC waveform | Pure Sine Wave |
Efficiency | > 88% |
GENERAL | |
LCD / LEDs Indications | UPS ON (Yellow), Battery Low (Red), Mains ON (Green),Charging (Green), Overload(Red) |
Alarms | Audible alarm indicates power failure and overload conditions |
Switches | 1)Switch control off / on power status |
2)Switch for mains input voltage range | |
3)Switch to select the maximum charging voltage | |
Protection | > 300% Load (with manual reset function) |
Cooling Method | Forced air cooled |
Transfer Time | Battery to line mode : 300 milliseconds / Line to battery mode : 300 milliseconds |
Housing Material | Powder coated / painted MS |
ENVIRONMENTAL | |
Operating Temperature Range | 0°C to 50°C |
Relative Humidity | 95% (non-condensing) |
Degree of Protection | IP 20 |
BATTERY | |
No of Battery | 16 |
Battery Charging Profile(Boost /Foat) | Suitable according to Battery type (eg :VRLA/SMF/Wet Lead Acid Battery) |
Max Charging Current(when battery is fully discharge) | 10A ±2amp |
SPECIAL FEATURES | |
Cold Start (startup in battery mode during a power failure) | Cold-start operation supported |
Charge End Voltage | Grid charging stop when battery reaches 13.8V ±0.2V and transfer to backup mode (per battery) |
Grid Recharge Voltage | Grid charging starts when battery reaches 11V ±0.2V and transfer to grid (per battery) |
CERTIFICATIONS | |
Quality Certifications | ISO 9001:2008 |
WARRANTY | |
Product Warranty Period | 1 – year limited warranty |